Safety
control units
The control that links the sensors to the machine’s safety function.
Safety mats · Bumpers · Safety edges
Between the sensor
and the machine, control.
A sensitive element detects contact. The control unit monitors its state and manages its own safety outputs.
The signal, monitored.
The choice of module starts from the type of sensor and the intended connection.
The right output.
Relays or semiconductors: different interfaces to be integrated into the machine architecture.
The reset, defined.
Manual or automatic, depending on the model and the assessment of the application.

Control.
The OSSD version.
A solution without electromechanical relays on the safety outputs. For projects that require this interface, with DC power supply and configurable reset.
- Power supply
- 12–24 Vdc
- Sensitive devices
- 2 / 4-wire
Different architectures.
An informed choice.
Explore the differences between the models, then look into connections and conditions in the respective manuals.

WASS1224
Solid-state outputs, with configurable reset and connection to two-wire or four-wire sensitive devices.
- Safety outputs
- Solid-state OSSD
- Sensitive element
- 2-wire with terminator / 4-wire
- Reset
- Manual or automatic

WACS24R
Guided-contact safety relays, for two-wire elements with terminator or four-wire elements.
- Safety outputs
- Guided-contact relays
- Sensitive element
- 2-wire with terminator / 4-wire
- Reset
- Manual or automatic

NC95
Module for four-wire sensitive devices, with manual reset only.
- Safety outputs
- Guided-contact relays
- Sensitive element
- 4-wire
- Reset
- Manual only

NC96MAT
Module for four-wire sensitive devices, with automatic reset only.
- Safety outputs
- Guided-contact relays
- Sensitive element
- 4-wire
- Reset
- Automatic only

WALR24/2A
Module for four-wire sensitive devices, with configurable reset.
- Safety outputs
- Guided-contact relays
- Sensitive element
- 4-wire
- Reset
- Manual or automatic
The comparison is a guide to the range: it does not replace the compatibility check, the manual or the validation of the complete function. The auxiliary signalling outputs are not safety outputs.
Not just a code.
A function to integrate.
Which sensor?
Type of device, number of conductors and termination: compatibility is checked on the actual combination.
Which outputs?
Relays or OSSD, interfaces and loads: the module is chosen together with the rest of the safety circuit.
Which reset?
Manual or automatic mode, to be defined with the risk assessment and the machine cycle. Resetting the outputs does not mean starting the machine.
The performance of the complete function depends on sensor, control unit, connections and actuators. Design, installation and validation must follow the relevant documentation.
The right information.
For every model.
Product manuals
Certificates and declarations
- TÜV · WASS1224PDF(PDF, opens in a new tab)
- TÜV · WACS24RPDF(PDF, opens in a new tab)
- TÜV · NC95 / NC96MATPDF(PDF, opens in a new tab)
- TÜV · WALR24/2APDF(PDF, opens in a new tab)
- UL · NC95 / NC96MATPDF(PDF, opens in a new tab)
- CE · NC95 / NC96MATPDF(PDF, opens in a new tab)
- REACH / RoHSPDF(PDF, opens in a new tab)
Refer to the document for the model and revision of the device. Certifications are not automatically extended to any machine configuration.
An existing installation.
The next step.
Replacing a WALR24? Start from the full model code and the machine wiring diagram. Here you will find resources to look into, without assuming automatic equivalences.
Go to support- From WALR24 to NC95 / NC96Replacement of WALR24 (WALR24A) with NC95/NC96
- WALR24 connection schemeWALR24 (WALR24A) connection scheme
- Operating principle and connectionConnection to safety control units
WALR24/2A and the previous model
The WALR24/2A safety control unit has been updated to comply with new safety regulations. The only differences for the user, compared to the model produced until 2018, are a new graphic design and a modification in the arrangement of the indicator LEDs, as shown in the figure. The wiring connection positions remain unchanged.

Control meets
the sensitive surface.
Let’s design the choice.
Together.
Tell us about the sensor, the machine and the intended integration. We start from there to find the right module.
Tell us about your application