Multi-zone
safety
mats
One surface.
Several distinct signals.
Not just presence.
Where it is.
The operating principle of the pressure-sensitive mat is unchanged. The surface is divided into areas, each with its own signal and a separate connection to the electronics.
They are discrete areas, defined in the design: not continuous location of a person.
Every zone.
Its own control unit.
Select an area.
Follow its signal.
Zone A highlighted · signal to control unit A.
To tell zones apart, wiring them
to the same input is not enough.
A control unit does not tell apart the zones wired to the same input: it knows a device has been pressed, not which area. If the machine has to react differently depending on the area, each zone gets its own control unit. Number of units, wiring and cabinet space are defined in the design.
Principle diagram, not to scale: three zones and three units are an example, not a standard configuration. The light volume shows the machine footprint. Orange marks the selection: it does not represent pressure, an alarm, a safety test or a mandatory product colour.
Safety and command.
Not the same thing.
Separate functions, on separate zones, with dedicated electronics that are not interchangeable.
The distinction starts from the assessment of the application.
Safety
An area that contributes to the machine stopping function, with suitable connection and electronics.
Detecting presenceCommand
An area used as a foot command, for a movement required by the process.
Requesting a movementA safety mat is not used as a switch to turn the machine on and off: the product manual forbids it. The complete function depends on mat, connections, control unit and actuators, and must be designed and validated on the machine.
Connections and the safety chain
The connection. The mat manual distinguishes 4 conductors for a safety connection and 2 conductors for signalling only. Which of the two applies depends on the function that zone has to perform, and is defined for the application.
The chain. Mat, control unit, connection and the actuator that stops the machine: safety performance is a property of the chain, not of a single part. With a suitable configuration and the WASS-1224 module, under the conditions stated in its manual, architectures up to Category 3 and PL e to EN ISO 13849-1 are documented. The type of connection is one of those conditions, not a guarantee: the Performance Level of the complete function depends on the whole architecture and on validation on the machine.
Which function is needed, where, and to what Category, follows from the machine risk assessment together with the architecture of the safety function.
Room for the zones.
The sizes to start from.
Two limits of our production, to tell straight away whether a layout is feasible.
They are not standard requirements or safety distances.
10 × 10cm
Minimum internal zone
Minimum size of a zone inside the mat.
25mm
Minimum distance between zones
Minimum separation between two internal zones of the same mat.
The geometry is made to measure.
Shape, dimensions, colours, cables and connectors are defined for the application, as for every WIDE pressure-sensitive mat.
Laying mats side by side is assessed too.
A single mat with two zones is feasible, but in practice the usual arrangement is several mats, each with its own zones. Mats are laid side by side, separated by an H profile: whether the result can be treated as a single protected surface is not a general rule, it depends on the arrangement, on the discontinuity between the sensitive surfaces and on the installation.



Around
the machine.
Inside the design.
An industrial plate rolling machine, overhead crane loading, the working space. How the areas are divided comes from the work done on the machine.
See the projectFrom the principle.
To the documents.
The configuration must be checked against the documentation of the devices chosen.
How many zones?
Let’s look at the machine.
A dimensioned sketch is enough to start.
No production drawing is needed.
- Footprint and dimensions of the area.
- Where the operator stands and how they move.
- Movements to be stopped or commanded.
- Safety electronics already on the machine.
We assess whether the device suits the application. Risk assessment, installation and validation of the complete safety function stay with the machine builder or the person responsible for safety, who knows the cycle and the working conditions.