News and insights
CorporatePress releases
5 min read
WASS1224 safety module on a DIN rail, with PWR, CH1 and CH2 status LEDs

WASS-1224: OSSD safety module for pressure sensitive devices, 12 to 24Vdc

Designing a safety system for pressure sensitive mats and edges means dealing with constraints that often have nothing to do with the protective device itself, but with the plant where it needs to be integrated. Available supply voltage, sensor wiring type, reset mode required by the machine logic, environment of use: these are variables that influence the choice of the safety module and, in many cases, limit it.

The new WASS-1224 is designed to reduce these constraints. It is a TÜV-certified safety module for the control of pressure sensitive devices in compliance with EN ISO 13856-1, EN ISO 13856-2, EN ISO 13856-3, EN 60204-1, EN ISO 13849-1 and EN ISO 13850. Solid–state OSSD outputs provide safe switching, avoiding the use of mechanical relays for safety channel monitoring.

Extended supply range: 12 to 24Vdc

The feature that immediately sets the WASS-1224 apart from most safety modules on the market is its supply voltage range: 12 ÷ 24Vdc with a ±15% tolerance. This means the module can be installed on 12V systems without the need for additional power supplies or redesigning the panel’s power distribution.

This is a tangible advantage in several application scenarios. In the retrofit of existing machines, where 24V may not be available or would require costly modifications. In mobile or battery-powered machines, where the nominal voltage is often 12V. In all situations where the designer wants to maintain maximum flexibility without compromising the safety level.

Compatibility with 2-wire and 4-wire devices

The WASS-1224 supports both 4-wire pressure sensitive devices (with separate channels) and 2-wire devices with an integrated 8.2 kΩ resistor. The distinction is not just a matter of wiring: the safety category achievable by the system depends on the type of device connected.

With a 4-wire device, or with a 2-wire device rated for category 3, the WASS-1224 system achieves safety category 3 and Performance Level PL-e according to EN ISO 13849-1, with a PFHd of 4.29 × 10⁻⁸ and an MTTFd of 100 years. With 2-wire devices not rated for category 3, the system operates at category 1 / PL-c, still with an MTTFd of 100 years.

In both cases, the safety outputs (terminals 13-14 and 23-24) are OSSD semiconductor type, short-circuit protected.

Manual or automatic reset: one configuration, not two products

The reset mode — monitored manual reset via pushbutton or automatic reset upon device release — is configured directly on the WASS-1224 terminals. For manual reset, a pushbutton is connected to terminals Y0-Y1; for automatic reset, terminals Y0-Y2 are simply bridged.

This flexibility eliminates the need to stock two product variants and simplifies order management when customer specifications may vary. The reset function, in both modes, complies with the requirements of Appendix A of EN ISO 13856-1, EN ISO 13856-2 and EN ISO 13856-3.

Emergency stop input

The WASS-1224 allows an emergency stop pushbutton to be connected in series with the pressure sensitive device, in compliance with EN ISO 13850 for stop category 0. Opening the X1-X2 input triggers a permanent safety condition: the outputs open and cannot be reclosed even by pressing the reset button, until the input itself is restored.

This feature makes it possible to integrate pressure sensitive device protection and emergency stop into a single module, reducing panel space and simplifying wiring.

Auxiliary outputs with configurable timing

In addition to the two safety outputs, the WASS-1224 features an NC auxiliary output (terminal 32) and an NO auxiliary output (terminal 33), both PNP type with a maximum current of 0.5A. These outputs can be configured in two operating modes via the AUX selector on the module.

In position “I” (instantaneous), the auxiliary outputs switch with the same timing as the safety outputs. In position “D” (delayed), the auxiliary output changes state 500ms after the falling edge of the X1-X2 input, provided the pulse duration exceeds 500ms. If the pulse exceeds 4500ms, the output returns to its rest state 4500ms from the edge regardless. Pulses shorter than 500ms do not cause any switching.

This function is useful for managing signalling, auxiliary interlocks or control logic that requires different timing from the main safety intervention.

Compact form factor and DIN rail mounting

The WASS-1224 measures 115 × 105 × 22.5 mm and weighs 165 g. It mounts on standard 35 mm DIN rail, inside an electrical panel or junction box with a protection rating of at least IP54. Connections are made via screw terminals.

The module operates in a temperature range from -5°C to +55°C, with storage conditions from -25°C to +70°C. The module’s own protection rating is IP20, overvoltage category is II and pollution degree is 2.

Key technical data

Supply voltage: 12 ÷ 24Vdc ±15%. Current consumption at 24Vdc: 25mA min, 70mA max. Output switching voltage: 10 ÷ 30Vdc. Switching current: 0.5A. Maximum output power: 15W. OFF response time: 10ms. Internal fuse: 300mA PTC. Recommended external fuse: 500mA gG (IEC EN 60269-1).

Safety category: Cat. 3 / PL-e with 4-wire or 2-wire cat. 3 devices; Cat. 1 / PL-c with standard 2-wire devices. Mission Time: 20 years (MTTFd = 100 years).

EMC compliance: EN 61326-3-1, EN 55011. Standards compliance: EN 60204-1, EN ISO 13849-1, EN ISO 13850, EN ISO 13856-1, EN ISO 13856-2, EN ISO 13856-3. Approval: TÜV IT 0948 25 MAC 513 B.

Availability

The WASS-1224 is available now. To request the full datasheet, wiring diagrams or a quotation, please contact our technical department or fill in the form on our contact page.

Published on Share on LinkedIn(opens in a new tab)
News archiveAll articles