{"id":30811,"date":"2026-09-22T08:06:01","date_gmt":"2026-09-22T06:06:01","guid":{"rendered":"https:\/\/www.wideautomation.com\/?p=30811"},"modified":"2026-09-10T12:56:04","modified_gmt":"2026-09-10T10:56:04","slug":"what-is-an-ossd-output","status":"publish","type":"post","link":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/","title":{"rendered":"What Is an OSSD Output"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container hundred-percent-fullwidth non-hundred-percent-height-scrolling wed wed-b wed-top\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:0px;--awb-padding-right:0px;--awb-padding-bottom:0px;--awb-padding-left:0px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"width:calc( 100% + 0px ) !important;max-width:calc( 100% + 0px ) !important;margin-left: calc(-0px \/ 2 );margin-right: calc(-0px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-margin-bottom-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"wed-wrap\"><a class=\"wed-back\" href=\"https:\/\/www.wideautomation.com\/en\/news\/\"><svg class=\"wed-ico\" width=\"16\" height=\"16\" viewBox=\"0 0 24 24\" aria-hidden=\"true\" focusable=\"false\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"m12 19-7-7 7-7\"\/><path d=\"M19 12H5\"\/><\/svg><span>News and insights<\/span><\/a><div class=\"wed-class\"><span>Focus<\/span><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container hundred-percent-fullwidth non-hundred-percent-height-scrolling wed wed-b wed-head wed-head-short\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:0px;--awb-padding-right:0px;--awb-padding-bottom:0px;--awb-padding-left:0px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"width:calc( 100% + 0px ) !important;max-width:calc( 100% + 0px ) !important;margin-left: calc(-0px \/ 2 );margin-right: calc(-0px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-margin-bottom-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"wed-wrap\"><div class=\"wed-meta\"><time datetime=\"2026-09-22\"><span class=\"wed-d\">22<\/span> September <span class=\"wed-d\">2026<\/span><\/time><span aria-hidden=\"true\">\u2022<\/span><span><span class=\"wed-d\">7<\/span> min read<\/span><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container hundred-percent-fullwidth non-hundred-percent-height-scrolling wed wed-b wed-body\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:0px;--awb-padding-right:0px;--awb-padding-bottom:0px;--awb-padding-left:0px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"width:calc( 100% + 0px ) !important;max-width:calc( 100% + 0px ) !important;margin-left: calc(-0px \/ 2 );margin-right: calc(-0px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_4 1_4 fusion-flex-column wed-aside-col\" style=\"--awb-bg-size:cover;--awb-width-large:25%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-margin-bottom-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><aside class=\"wed-aside\"><nav aria-label=\"Article contents\"><span class=\"wed-k\">In this article<\/span><a href=\"#wed-s1\">What an OSSD output does that a contact does not<\/a><a href=\"#wed-s2\">Test pulses: what they are for<\/a><a href=\"#wed-s3\">OSSD is the unit's output, not the sensor's signal<\/a><a href=\"#wed-s4\">OSSD, relay contacts and the control unit: three different things<\/a><a href=\"#wed-s5\">And what about \"safety relays\"?<\/a><a href=\"#wed-s6\">How a pressure-sensitive device is connected<\/a><a href=\"#wed-s7\">When you need an OSSD output<\/a><a href=\"#wed-s8\">Why the output alone is not enough: the Performance Level belongs to the chain<\/a><a href=\"#wed-s9\">In short<\/a><\/nav><div class=\"wed-aside-end\"><span class=\"wed-k\">Share<\/span><a href=\"https:\/\/www.linkedin.com\/sharing\/share-offsite\/?url=https%3A%2F%2Fwww.wideautomation.com%2Fen%2Fwhat-is-an-ossd-output%2F\" target=\"_blank\" rel=\"noopener\"><span>LinkedIn<\/span><span class=\"screen-reader-text\">(opens in a new tab)<\/span><svg class=\"wed-ico\" width=\"16\" height=\"16\" viewBox=\"0 0 24 24\" aria-hidden=\"true\" focusable=\"false\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M7 7h10v10\"\/><path d=\"M7 17 17 7\"\/><\/svg><\/a><a href=\"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/\"><span>Article link<\/span><svg class=\"wed-ico\" width=\"16\" height=\"16\" viewBox=\"0 0 24 24\" aria-hidden=\"true\" focusable=\"false\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M10 13a5 5 0 0 0 7.54.54l3-3a5 5 0 0 0-7.07-7.07l-1.72 1.71\"\/><path d=\"M14 11a5 5 0 0 0-7.54-.54l-3 3a5 5 0 0 0 7.07 7.07l1.71-1.71\"\/><\/svg><\/a><\/div><\/aside><details class=\"wed-mtoc\"><summary><span>In this article<\/span><svg class=\"wed-ico wed-chev\" width=\"16\" height=\"16\" viewBox=\"0 0 24 24\" aria-hidden=\"true\" focusable=\"false\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"m6 9 6 6 6-6\"\/><\/svg><\/summary><nav aria-label=\"Article contents on mobile\"><a href=\"#wed-s1\">What an OSSD output does that a contact does not<\/a><a href=\"#wed-s2\">Test pulses: what they are for<\/a><a href=\"#wed-s3\">OSSD is the unit's output, not the sensor's signal<\/a><a href=\"#wed-s4\">OSSD, relay contacts and the control unit: three different things<\/a><a href=\"#wed-s5\">And what about \"safety relays\"?<\/a><a href=\"#wed-s6\">How a pressure-sensitive device is connected<\/a><a href=\"#wed-s7\">When you need an OSSD output<\/a><a href=\"#wed-s8\">Why the output alone is not enough: the Performance Level belongs to the chain<\/a><a href=\"#wed-s9\">In short<\/a><\/nav><\/details><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_3_4 3_4 fusion-flex-column wed-reading\" style=\"--awb-bg-size:cover;--awb-width-large:75%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-margin-bottom-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1 wed-text\" style=\"--awb-text-transform:none;--awb-margin-top:2%;\"><p><strong>OSSD stands for <em>Output Signal Switching Device<\/em>: it is an electronic safety output, solid-state, that not only switches but continuously checks that it is still able to switch.<\/strong> You find it on the output side of a safety control unit \u2014 a light curtain, a laser scanner, a safety module \u2014 heading towards the machine logic.<\/p>\n<p>In the world of pressure-sensitive devices the acronym causes one recurring confusion, and clearing it up is what this page is for: <strong>OSSD describes what leaves the control unit, not what enters it from the sensor<\/strong>.<\/p>\n<h2 id=\"wed-s1\">What an OSSD output does that a contact does not<\/h2>\n<p>A conventional electromechanical contact says &#8220;I am open&#8221; or &#8220;I am closed&#8221;. Until something tests it, there is no way to know whether it is still able to open: a welded contact keeps reporting its state long after it has lost the ability to change it.<\/p>\n<p>An OSSD output monitors itself and its own wiring. If it detects an abnormal condition \u2014 a short circuit between the two channels, or towards the supply \u2014 it drives the outputs to the safe state <strong>without waiting for the next demand<\/strong>. It is this continuous self-diagnosis, not the technology as such, that sets it apart.<\/p>\n<p>OSSD outputs normally come in pairs and work together: the redundancy exists so that a failure in one channel does not remove the safety function.<\/p>\n<h2 id=\"wed-s2\">Test pulses: what they are for<\/h2>\n<p>To verify channel integrity, OSSD outputs carry short test pulses superimposed on the signal. During a pulse the output switches for a very short time and the circuit checks that the switching actually happens.<\/p>\n<p>This is why connecting an OSSD output to an input that is not designed for it \u2014 a standard PLC, a general-purpose relay, an unfiltered input \u2014 can produce trips that look inexplicable: the input reads the test pulses as state changes.<\/p>\n<p><strong>Pulse duration, frequency, phase shift and current are not specified in the public documentation of our products, and we do not report them here.<\/strong> If you need to interface the output to a particular machine logic, ask for them explicitly at design stage: they are integration data, not a detail.<\/p>\n<h2 id=\"wed-s3\">OSSD is the unit&#8217;s output, not the sensor&#8217;s signal<\/h2>\n<p>This is the point that justifies the page, and the most common misunderstanding among people searching for &#8220;OSSD&#8221;.<\/p>\n<p>A <a href=\"https:\/\/www.wideautomation.com\/en\/products\/sensitive-mats\/\">safety mat<\/a>, a <a href=\"https:\/\/www.wideautomation.com\/en\/products\/sensitive-edges\/\">safety edge<\/a> or a <a href=\"https:\/\/www.wideautomation.com\/en\/products\/sensitive-bumpers\/\">safety bumper<\/a> is a <strong>passive device<\/strong>: it changes an electrical quantity when someone presses it, and nothing else. It does not diagnose, does not switch a safety circuit, does not notice its own failure.<\/p>\n<p>Upstream of the unit, then, the device does not speak &#8220;in OSSD&#8221;. It speaks one of the two languages of its wiring: <strong>4-wire contacts on two channels<\/strong>, or a <strong>2-wire circuit with a termination resistor<\/strong>. The OSSD signal is born downstream, inside the control unit.<\/p>\n<p>Anyone looking for &#8220;an OSSD sensor&#8221; and expecting the mat to produce that signal directly is looking for the wrong thing. The useful question is a different one: <em>which control unit does this device need, and which output type do I need towards the machine?<\/em><\/p>\n<h2 id=\"wed-s4\">OSSD, relay contacts and the control unit: three different things<\/h2>\n<p>These are three distinct levels, and it is worth keeping them apart.<\/p>\n<ul>\n<li><strong>The safety control unit<\/strong> \u2014 module, or safety control module \u2014 is the device. It receives the signal from the pressure-sensitive element, interprets it, monitors itself and commands the stop.<\/li>\n<li><strong>Relay outputs with forcibly guided contacts<\/strong> are one way of building the unit&#8217;s safety output: physical contacts, with a mechanical linkage that prevents a normally open and a normally closed contact from being closed at the same time.<\/li>\n<li><strong>OSSD outputs<\/strong> are the other way: electronic, solid-state, self-diagnosing.<\/li>\n<\/ul>\n<p>Neither is better in absolute terms. Relay contacts carry higher voltages and currents and interface with any logic; OSSD outputs have no mechanical wear, switch faster and diagnose the wiring, but they require inputs designed to receive them.<\/p>\n<p>Both live in our range of <a href=\"https:\/\/www.wideautomation.com\/en\/products\/safety-control-units\/\">safety control units<\/a>: <strong>four units have relay outputs with forcibly guided contacts<\/strong> \u2014 WACS-24R, NC95, NC96 MAT and WARL24-2A \u2014 and <strong>one has OSSD semiconductor outputs<\/strong>, the WASS-1224.<\/p>\n<h2 id=\"wed-s5\">And what about &#8220;safety relays&#8221;?<\/h2>\n<p>Most people searching for a <strong>safety relay<\/strong> have something specific in mind: a <strong>general-purpose safety logic module<\/strong>, DIN-rail mounted, that accepts inputs from any device and is sold from a catalogue. Ask &#8220;how does a safety relay work&#8221; and the answer you get is about that class of product.<\/p>\n<p>Our units are something else: they are <strong>dedicated to pressure-sensitive devices<\/strong>. They read a specific signal \u2014 resistive, or dual-contact \u2014 that a general-purpose module is not designed to interpret. The distinction is not &#8220;relay or not relay&#8221;: it is <strong>general-purpose versus dedicated<\/strong>.<\/p>\n<p>So if you arrived here looking for a safety relay and you have to connect a mat, an edge or a bumper, the term that will actually find what you need is <strong>safety control unit<\/strong>, or safety module for pressure-sensitive devices.<\/p>\n<h2 id=\"wed-s6\">How a pressure-sensitive device is connected<\/h2>\n<p>Upstream of the unit there are two documented ways, and the choice is not neutral.<\/p>\n<p><strong>4-wire contact, two channels.<\/strong> The device opens or closes two independent circuits. This is the connection used by the Standard series edges, which the datasheets in revision 01-04-2026 declare compatible with all five of our units.<\/p>\n<p><strong>Two wires with an 8.2 k\u03a9 termination resistor.<\/strong> A single circuit, in which the unit distinguishes rest, actuation and fault by reading the resistance value. This is the connection used by the COE series edges, which the datasheet declares compatible with <strong>WACS-24R and WASS-1224<\/strong>: the other three units are not listed, and we do not add them by analogy.<\/p>\n<p>On the WASS-1224 the thresholds stated in the manual are above 13.8 k\u03a9 and below 3.8 k\u03a9. This is why cable length is not a logistical detail: it affects line resistance and therefore threshold recognition in 2-wire circuits.<\/p>\n<p><strong>A note on compatibility.<\/strong> The combinations listed above are those <strong>explicitly declared<\/strong> in published documents. For mats, the explicitly documented pairing is the one with the WASS-1224; for the bumper there is no public datasheet declaring compatible units. Combinations that are not documented are not &#8220;forbidden&#8221;: they are <strong>to be confirmed case by case with our technical department<\/strong>, and we do not declare them here. The maximum number of elements that can be connected in series, where stated, is ten: it applies to the Standard series and to the COE series on WACS-24R and WASS-1224, and it must not be extended to the other units.<\/p>\n<h2 id=\"wed-s7\">When you need an OSSD output<\/h2>\n<p>Three typical situations where the electronic output is the natural choice:<\/p>\n<ul>\n<li>the downstream machine logic has <strong>safety inputs designed to receive it<\/strong>, as safety PLCs and many drives do;<\/li>\n<li>the expected number of operations is high and you want to avoid contact wear;<\/li>\n<li>you want the wiring towards the machine to be monitored, not merely switched.<\/li>\n<\/ul>\n<p>Relay contacts remain preferable in other cases: voltages or currents beyond the reach of an electronic output, interfacing with logic that is not designed for OSSD, or simply an existing installation that already uses them.<\/p>\n<p>One last warning, because it is a mistake we see often: some units have an <strong>auxiliary output<\/strong> for signalling. <strong>It is not a safety output<\/strong> and must not be placed in the safety chain, however convenient that may look.<\/p>\n<h2 id=\"wed-s8\">Why the output alone is not enough: the Performance Level belongs to the chain<\/h2>\n<p>One final clarification, because it follows directly from all of the above. The fact that a unit has OSSD outputs <strong>does not by itself assign it a Performance Level<\/strong>, and it certainly does not assign one to the sensor you connect to it.<\/p>\n<p>The WASS-1224 itself documents <strong>Category 1 and PL c<\/strong> with a 2-wire device, and <strong>Category 3 and PL e<\/strong> with a 4-wire device or a 2-wire device in category 3. Same unit, same OSSD outputs, two levels apart: what changes is the wiring. The full reasoning is in our guide to <a href=\"https:\/\/www.wideautomation.com\/en\/performance-level-iso-13849-1-pressure-sensitive-devices\/\">Performance Level and ISO 13849-1<\/a>.<\/p>\n<h2 id=\"wed-s9\">In short<\/h2>\n<ul>\n<li><strong>OSSD<\/strong> = a self-diagnosing solid-state safety output, sitting <strong>on the output side of the control unit<\/strong>.<\/li>\n<li>A pressure-sensitive device <strong>does not produce an OSSD signal<\/strong>: it is passive and connects with 2 or 4 wires.<\/li>\n<li><strong>OSSD outputs and relay outputs with forcibly guided contacts<\/strong> are two ways of building the safety output of the same unit.<\/li>\n<li><strong>Test pulse parameters<\/strong> are not published: ask for them at design stage.<\/li>\n<li><strong>Compatibility<\/strong> holds only where it is declared: everything else is confirmed case by case.<\/li>\n<\/ul>\n<p>Wiring schemes between pressure-sensitive elements and control units are collected in the <a href=\"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/\">dedicated technical sheet<\/a>.<\/p>\n<p><strong>Need to connect a pressure-sensitive device and unsure which unit it takes?<\/strong> Tell us the wiring you have and the machine logic: we will tell you which unit fits and which output type you need.<\/p>\n<\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-1 fusion-button-default-span wed-btn\" style=\"--button_accent_color:#ffffff;--button_accent_hover_color:#f59c00;--button_border_hover_color:#f59c00;--button-border-radius-top-left:50px;--button-border-radius-top-right:50px;--button-border-radius-bottom-right:50px;--button-border-radius-bottom-left:50px;--button_gradient_top_color:#f59c00;--button_gradient_bottom_color:#f59c00;--button_gradient_top_color_hover:#ffffff;--button_gradient_bottom_color_hover:#ffffff;\" target=\"_self\" href=\"https:\/\/www.wideautomation.com\/en\/contacts\/\"><i class=\"fa-shield-alt fas awb-button__icon awb-button__icon--default button-icon-left\" aria-hidden=\"true\"><\/i><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Ask which unit you need<\/span><\/a><\/div><div class=\"wed-end\"><span>Published on <time datetime=\"2026-09-22\"><span class=\"wed-d\">22<\/span> September <span class=\"wed-d\">2026<\/span><\/time><\/span><a href=\"https:\/\/www.linkedin.com\/sharing\/share-offsite\/?url=https%3A%2F%2Fwww.wideautomation.com%2Fen%2Fwhat-is-an-ossd-output%2F\" target=\"_blank\" rel=\"noopener\"><span>Share on LinkedIn<\/span><span class=\"screen-reader-text\">(opens in a new tab)<\/span><svg class=\"wed-ico\" width=\"16\" height=\"16\" viewBox=\"0 0 24 24\" aria-hidden=\"true\" focusable=\"false\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M7 7h10v10\"\/><path d=\"M7 17 17 7\"\/><\/svg><\/a><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container hundred-percent-fullwidth non-hundred-percent-height-scrolling wed wed-b wed-archive\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:0px;--awb-padding-right:0px;--awb-padding-bottom:0px;--awb-padding-left:0px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"width:calc( 100% + 0px ) !important;max-width:calc( 100% + 0px ) !important;margin-left: calc(-0px \/ 2 );margin-right: calc(-0px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-margin-bottom-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"wed-wrap\"><div class=\"wed-rel-head\"><span class=\"wed-k\">News archive<\/span><a href=\"https:\/\/www.wideautomation.com\/en\/news\/\"><span>All articles<\/span><svg class=\"wed-ico\" width=\"16\" height=\"16\" viewBox=\"0 0 24 24\" aria-hidden=\"true\" focusable=\"false\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M7 7h10v10\"\/><path d=\"M7 17 17 7\"\/><\/svg><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":30837,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[139],"tags":[156],"class_list":["post-30811","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-focus-en-2","tag-hero-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What Is an OSSD Output and When You Need One<\/title>\n<meta name=\"description\" content=\"OSSD is the self-diagnosing safety output of a control unit, not the sensor&#039;s signal. How it differs from relay outputs, and when to use it.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Is an OSSD Output and When You Need One\" \/>\n<meta property=\"og:description\" content=\"OSSD is the self-diagnosing safety output of a control unit, not the sensor&#039;s signal. How it differs from relay outputs, and when to use it.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/\" \/>\n<meta property=\"og:site_name\" content=\"WIDE Automation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/wideautomation\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-22T06:06:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/09\/10125407\/OSSD-wide-automation-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"1009\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"WIDE Automation\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@wideautomation\" \/>\n<meta name=\"twitter:site\" content=\"@wideautomation\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"WIDE Automation\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/\"},\"author\":{\"name\":\"WIDE Automation\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#\\\/schema\\\/person\\\/ce8625bdace43d31de37470d57ec0bbb\"},\"headline\":\"What Is an OSSD Output\",\"datePublished\":\"2026-09-22T06:06:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/\"},\"wordCount\":2931,\"publisher\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2026\\\/09\\\/10125407\\\/OSSD-wide-automation-scaled.jpg\",\"keywords\":[\"hero\"],\"articleSection\":[\"Focus\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/\",\"url\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/\",\"name\":\"What Is an OSSD Output and When You Need One\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2026\\\/09\\\/10125407\\\/OSSD-wide-automation-scaled.jpg\",\"datePublished\":\"2026-09-22T06:06:01+00:00\",\"description\":\"OSSD is the self-diagnosing safety output of a control unit, not the sensor's signal. How it differs from relay outputs, and when to use it.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2026\\\/09\\\/10125407\\\/OSSD-wide-automation-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2026\\\/09\\\/10125407\\\/OSSD-wide-automation-scaled.jpg\",\"width\":1600,\"height\":1009,\"caption\":\"OSSD outputs for WIDE Automation industrial safety devices\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/what-is-an-ossd-output\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Is an OSSD Output\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/\",\"name\":\"WIDE Automation\",\"description\":\"Industrial Automation and Machine Safety\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#organization\",\"name\":\"WIDE Automation\",\"url\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2018\\\/07\\\/01230055\\\/WIDE_favicon.png\",\"contentUrl\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2018\\\/07\\\/01230055\\\/WIDE_favicon.png\",\"width\":579,\"height\":579,\"caption\":\"WIDE Automation\"},\"image\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/wideautomation\\\/\",\"https:\\\/\\\/x.com\\\/wideautomation\",\"https:\\\/\\\/www.instagram.com\\\/wideautomation\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/wideautomation\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UChAVD04YAodNLwzozxaY3aQ\"],\"description\":\"WIDE Automation develops and manufactures safety devices and motion control solutions configured around the application.\",\"legalName\":\"WIDE Automation S.r.l.\",\"vatID\":\"IT03235230400\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Via Malpasso 1340\",\"addressLocality\":\"San Giovanni in Marignano\",\"addressRegion\":\"RN\",\"postalCode\":\"47842\",\"addressCountry\":\"IT\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#\\\/schema\\\/person\\\/ce8625bdace43d31de37470d57ec0bbb\",\"name\":\"WIDE Automation\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b9adfc5398ff41b9f8277d568714c8715af9ac7b79b83d6018789a6b5aac7f87?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b9adfc5398ff41b9f8277d568714c8715af9ac7b79b83d6018789a6b5aac7f87?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b9adfc5398ff41b9f8277d568714c8715af9ac7b79b83d6018789a6b5aac7f87?s=96&d=mm&r=g\",\"caption\":\"WIDE Automation\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Is an OSSD Output and When You Need One","description":"OSSD is the self-diagnosing safety output of a control unit, not the sensor's signal. How it differs from relay outputs, and when to use it.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/","og_locale":"en_US","og_type":"article","og_title":"What Is an OSSD Output and When You Need One","og_description":"OSSD is the self-diagnosing safety output of a control unit, not the sensor's signal. How it differs from relay outputs, and when to use it.","og_url":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/","og_site_name":"WIDE Automation","article_publisher":"https:\/\/www.facebook.com\/wideautomation\/","article_published_time":"2026-09-22T06:06:01+00:00","og_image":[{"width":1600,"height":1009,"url":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/09\/10125407\/OSSD-wide-automation-scaled.jpg","type":"image\/jpeg"}],"author":"WIDE Automation","twitter_card":"summary_large_image","twitter_creator":"@wideautomation","twitter_site":"@wideautomation","twitter_misc":{"Written by":"WIDE Automation","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#article","isPartOf":{"@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/"},"author":{"name":"WIDE Automation","@id":"https:\/\/www.wideautomation.com\/en\/#\/schema\/person\/ce8625bdace43d31de37470d57ec0bbb"},"headline":"What Is an OSSD Output","datePublished":"2026-09-22T06:06:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/"},"wordCount":2931,"publisher":{"@id":"https:\/\/www.wideautomation.com\/en\/#organization"},"image":{"@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#primaryimage"},"thumbnailUrl":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/09\/10125407\/OSSD-wide-automation-scaled.jpg","keywords":["hero"],"articleSection":["Focus"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/","url":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/","name":"What Is an OSSD Output and When You Need One","isPartOf":{"@id":"https:\/\/www.wideautomation.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#primaryimage"},"image":{"@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#primaryimage"},"thumbnailUrl":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/09\/10125407\/OSSD-wide-automation-scaled.jpg","datePublished":"2026-09-22T06:06:01+00:00","description":"OSSD is the self-diagnosing safety output of a control unit, not the sensor's signal. How it differs from relay outputs, and when to use it.","breadcrumb":{"@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#primaryimage","url":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/09\/10125407\/OSSD-wide-automation-scaled.jpg","contentUrl":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/09\/10125407\/OSSD-wide-automation-scaled.jpg","width":1600,"height":1009,"caption":"OSSD outputs for WIDE Automation industrial safety devices"},{"@type":"BreadcrumbList","@id":"https:\/\/www.wideautomation.com\/en\/what-is-an-ossd-output\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.wideautomation.com\/en\/"},{"@type":"ListItem","position":2,"name":"What Is an OSSD Output"}]},{"@type":"WebSite","@id":"https:\/\/www.wideautomation.com\/en\/#website","url":"https:\/\/www.wideautomation.com\/en\/","name":"WIDE Automation","description":"Industrial Automation and Machine Safety","publisher":{"@id":"https:\/\/www.wideautomation.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.wideautomation.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.wideautomation.com\/en\/#organization","name":"WIDE Automation","url":"https:\/\/www.wideautomation.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.wideautomation.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2018\/07\/01230055\/WIDE_favicon.png","contentUrl":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2018\/07\/01230055\/WIDE_favicon.png","width":579,"height":579,"caption":"WIDE Automation"},"image":{"@id":"https:\/\/www.wideautomation.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/wideautomation\/","https:\/\/x.com\/wideautomation","https:\/\/www.instagram.com\/wideautomation","https:\/\/www.linkedin.com\/company\/wideautomation\/","https:\/\/www.youtube.com\/channel\/UChAVD04YAodNLwzozxaY3aQ"],"description":"WIDE Automation develops and manufactures safety devices and motion control solutions configured around the application.","legalName":"WIDE Automation S.r.l.","vatID":"IT03235230400","address":{"@type":"PostalAddress","streetAddress":"Via Malpasso 1340","addressLocality":"San Giovanni in Marignano","addressRegion":"RN","postalCode":"47842","addressCountry":"IT"}},{"@type":"Person","@id":"https:\/\/www.wideautomation.com\/en\/#\/schema\/person\/ce8625bdace43d31de37470d57ec0bbb","name":"WIDE Automation","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b9adfc5398ff41b9f8277d568714c8715af9ac7b79b83d6018789a6b5aac7f87?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b9adfc5398ff41b9f8277d568714c8715af9ac7b79b83d6018789a6b5aac7f87?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b9adfc5398ff41b9f8277d568714c8715af9ac7b79b83d6018789a6b5aac7f87?s=96&d=mm&r=g","caption":"WIDE Automation"}}]}},"_links":{"self":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/posts\/30811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/comments?post=30811"}],"version-history":[{"count":1,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/posts\/30811\/revisions"}],"predecessor-version":[{"id":30816,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/posts\/30811\/revisions\/30816"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/media\/30837"}],"wp:attachment":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/media?parent=30811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/categories?post=30811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/tags?post=30811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}