{"id":18089,"date":"2019-02-15T20:52:04","date_gmt":"2019-02-15T18:52:04","guid":{"rendered":"https:\/\/www.wideautomation.com\/?post_type=avada_portfolio&#038;p=18089"},"modified":"2026-09-09T10:33:30","modified_gmt":"2026-09-09T08:33:30","slug":"operating-principle-and-connection-to-safety-control-units","status":"publish","type":"avada_portfolio","link":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/","title":{"rendered":"Operating principle and connection to safety control units"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:-80px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-padding-bottom:5px;--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-1\"><h1>Operating principle and connection to safety control units<\/h1>\n<\/div><div class=\"fusion-button-wrapper fusion-alignleft\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-1 fusion-button-default-span fusion-button-default-type wide-l04-download\" style=\"--button_accent_color:#f59c00;--button_border_color:#f59c00;--button_accent_hover_color:#f6f6f6;--button_border_hover_color:#f59c00;--button_border_width-top:0;--button_border_width-right:0;--button_border_width-bottom:0;--button_border_width-left:0;--button_gradient_top_color:rgba(255,255,255,0);--button_gradient_bottom_color:rgba(255,255,255,0);--button_gradient_top_color_hover:#f59c00;--button_gradient_bottom_color_hover:#f59c00;\" target=\"_blank\" rel=\"noopener noreferrer\" title=\"Operating principle and connection to safety control units - PDF in English\" aria-label=\"Operating principle and connection to safety control units - PDF in English\" href=\"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2026\/10\/20231733\/WIDE-principio-collegamento-elementi-sensibili-EN-R1.pdf\"><i class=\"fa-file-pdf far awb-button__icon awb-button__icon--default button-icon-left\" aria-hidden=\"true\"><\/i><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Download the PDF<\/span><\/a><\/div><div class=\"fusion-text fusion-text-2 wide-l04-download\"><p style=\"clear:both\">PDF in English, R1 editorial revision of 20\/10\/2026, 1 page: text and connection diagrams, with the brown\u2013yellow conductor pair stated correctly. It does not replace the applicable manuals or safety-function verification.<\/p>\n<p>Archived original document: <a href=\"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2024\/05\/13142015\/operating-principle-safety-elements.pdf\" target=\"_blank\" rel=\"noopener\">Operating principle of the safety elements (PDF, 2024)<\/a>; the R1 revision corrects the conductor designation.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-first fusion-column-inner-bg-wrapper\" style=\"--awb-inner-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );margin-right: 4%;\"><span class=\"fusion-column-inner-bg hover-type-zoomin\"><span class=\"fusion-column-anchor\"><span class=\"fusion-column-inner-bg-image\"><\/span><\/span><\/span><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" alt=\"Operating principle of WIDE pressure-sensitive elements and connection to the safety control unit\" src=\"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2018\/12\/01221243\/Operating-principle-and-connection-to-safety-control-units-02.jpg\" class=\"img-responsive\"\/><\/span><\/div><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-div\" style=\"--awb-margin-top:5px;--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><div class=\"fusion-title-heading title-heading-left title-heading-tag fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:20;--minFontSize:20;line-height:1.5;\"><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last fusion-column-inner-bg-wrapper\" style=\"--awb-inner-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );\"><span class=\"fusion-column-inner-bg hover-type-zoomin\"><span class=\"fusion-column-anchor\"><span class=\"fusion-column-inner-bg-image\"><\/span><\/span><\/span><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" alt=\"Wiring diagram of pressure-sensitive elements connected to a WIDE safety control unit\" src=\"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2018\/12\/01221322\/Funzionamento-elementi-sensibili-collegamento-in-cascata-wide-automation3-1.jpg\" class=\"img-responsive\"\/><\/span><\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-div\" style=\"--awb-margin-top:5px;--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><div class=\"fusion-title-heading title-heading-left title-heading-tag fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:20;--minFontSize:20;line-height:1.5;\"><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-3\"><div class=\"page\" title=\"Page 1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>The continuity of the sensitive elements is monitored by checking the electrical continuity between the conductors respectively <strong>white-green<\/strong> and <strong>brown-yellow<\/strong>.<\/p>\n<\/div>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>If an interruption occurs between the white-green and\/or brown-yellow conductors, the safety control unit reacts by opening the contacts of the safety relays (which are normally closed).<\/p>\n<p>The sensitive element behaves like a <strong>normally open contact<\/strong>. The pressure of the sensitive element causes a closing of the contact with consequent<strong> closure of the circuit<\/strong> between all 4 conductors.<\/p>\n<p>It is possible to put <strong>multiple elements in cascade<\/strong>, using the following scheme.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-div\" style=\"--awb-margin-top:5px;--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><div class=\"fusion-title-heading title-heading-center title-heading-tag fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:20;--minFontSize:20;line-height:1.5;\"><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_6 1_6 fusion-one-sixth fusion-column-first\" style=\"--awb-bg-size:cover;width:16.666666666667%;width:calc(16.666666666667% - ( ( 4% + 4% ) * 0.16666666666667 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_2_3 2_3 fusion-two-third\" style=\"--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% + 4% ) * 0.66666666666667 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" alt=\"Several pressure-sensitive elements connected in cascade to a single safety control unit\" src=\"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2019\/03\/01221154\/Funzionamento-elementi-sensibili-collegamento-in-cascata-wide-automation2.jpg\" class=\"img-responsive\"\/><\/span><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_6 1_6 fusion-one-sixth fusion-column-last\" style=\"--awb-bg-size:cover;width:16.666666666667%;width:calc(16.666666666667% - ( ( 4% + 4% ) * 0.16666666666667 ) );\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"portfolio_category":[],"portfolio_skills":[],"portfolio_tags":[],"class_list":["post-18089","avada_portfolio","type-avada_portfolio","status-publish","format-standard","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Operating Principle and Connection to Safety Control Units<\/title>\n<meta name=\"description\" content=\"How pressure-sensitive elements work and how they are wired to a safety control unit, with the reference document to download.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Operating Principle and Connection to Safety Control Units\" \/>\n<meta property=\"og:description\" content=\"How pressure-sensitive elements work and how they are wired to a safety control unit, with the reference document to download.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/\" \/>\n<meta property=\"og:site_name\" content=\"WIDE Automation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/wideautomation\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-09T08:33:30+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@wideautomation\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/doc\\\/operating-principle-and-connection-to-safety-control-units\\\/\",\"url\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/doc\\\/operating-principle-and-connection-to-safety-control-units\\\/\",\"name\":\"Operating Principle and Connection to Safety Control Units\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#website\"},\"datePublished\":\"2019-02-15T18:52:04+00:00\",\"dateModified\":\"2026-09-09T08:33:30+00:00\",\"description\":\"How pressure-sensitive elements work and how they are wired to a safety control unit, with the reference document to download.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/doc\\\/operating-principle-and-connection-to-safety-control-units\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/doc\\\/operating-principle-and-connection-to-safety-control-units\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/doc\\\/operating-principle-and-connection-to-safety-control-units\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Portfolio\",\"item\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/doc\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Operating principle and connection to safety control units\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/\",\"name\":\"WIDE Automation\",\"description\":\"Industrial Automation and Machine Safety\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#organization\",\"name\":\"WIDE Automation\",\"url\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2018\\\/07\\\/01230055\\\/WIDE_favicon.png\",\"contentUrl\":\"https:\\\/\\\/cdn1.wideautomation.com\\\/media\\\/uploads\\\/2018\\\/07\\\/01230055\\\/WIDE_favicon.png\",\"width\":579,\"height\":579,\"caption\":\"WIDE Automation\"},\"image\":{\"@id\":\"https:\\\/\\\/www.wideautomation.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/wideautomation\\\/\",\"https:\\\/\\\/x.com\\\/wideautomation\",\"https:\\\/\\\/www.instagram.com\\\/wideautomation\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/wideautomation\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UChAVD04YAodNLwzozxaY3aQ\"],\"description\":\"WIDE Automation develops and manufactures safety devices and motion control solutions configured around the application.\",\"legalName\":\"WIDE Automation S.r.l.\",\"vatID\":\"IT03235230400\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Via Malpasso 1340\",\"addressLocality\":\"San Giovanni in Marignano\",\"addressRegion\":\"RN\",\"postalCode\":\"47842\",\"addressCountry\":\"IT\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Operating Principle and Connection to Safety Control Units","description":"How pressure-sensitive elements work and how they are wired to a safety control unit, with the reference document to download.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/","og_locale":"en_US","og_type":"article","og_title":"Operating Principle and Connection to Safety Control Units","og_description":"How pressure-sensitive elements work and how they are wired to a safety control unit, with the reference document to download.","og_url":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/","og_site_name":"WIDE Automation","article_publisher":"https:\/\/www.facebook.com\/wideautomation\/","article_modified_time":"2026-09-09T08:33:30+00:00","twitter_card":"summary_large_image","twitter_site":"@wideautomation","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/","url":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/","name":"Operating Principle and Connection to Safety Control Units","isPartOf":{"@id":"https:\/\/www.wideautomation.com\/en\/#website"},"datePublished":"2019-02-15T18:52:04+00:00","dateModified":"2026-09-09T08:33:30+00:00","description":"How pressure-sensitive elements work and how they are wired to a safety control unit, with the reference document to download.","breadcrumb":{"@id":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.wideautomation.com\/en\/doc\/operating-principle-and-connection-to-safety-control-units\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.wideautomation.com\/en\/"},{"@type":"ListItem","position":2,"name":"Portfolio","item":"https:\/\/www.wideautomation.com\/en\/doc\/"},{"@type":"ListItem","position":3,"name":"Operating principle and connection to safety control units"}]},{"@type":"WebSite","@id":"https:\/\/www.wideautomation.com\/en\/#website","url":"https:\/\/www.wideautomation.com\/en\/","name":"WIDE Automation","description":"Industrial Automation and Machine Safety","publisher":{"@id":"https:\/\/www.wideautomation.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.wideautomation.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.wideautomation.com\/en\/#organization","name":"WIDE Automation","url":"https:\/\/www.wideautomation.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.wideautomation.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2018\/07\/01230055\/WIDE_favicon.png","contentUrl":"https:\/\/cdn1.wideautomation.com\/media\/uploads\/2018\/07\/01230055\/WIDE_favicon.png","width":579,"height":579,"caption":"WIDE Automation"},"image":{"@id":"https:\/\/www.wideautomation.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/wideautomation\/","https:\/\/x.com\/wideautomation","https:\/\/www.instagram.com\/wideautomation","https:\/\/www.linkedin.com\/company\/wideautomation\/","https:\/\/www.youtube.com\/channel\/UChAVD04YAodNLwzozxaY3aQ"],"description":"WIDE Automation develops and manufactures safety devices and motion control solutions configured around the application.","legalName":"WIDE Automation S.r.l.","vatID":"IT03235230400","address":{"@type":"PostalAddress","streetAddress":"Via Malpasso 1340","addressLocality":"San Giovanni in Marignano","addressRegion":"RN","postalCode":"47842","addressCountry":"IT"}}]}},"_links":{"self":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/avada_portfolio\/18089","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/avada_portfolio"}],"about":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/types\/avada_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/comments?post=18089"}],"version-history":[{"count":4,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/avada_portfolio\/18089\/revisions"}],"predecessor-version":[{"id":30831,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/avada_portfolio\/18089\/revisions\/30831"}],"wp:attachment":[{"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/media?parent=18089"}],"wp:term":[{"taxonomy":"portfolio_category","embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/portfolio_category?post=18089"},{"taxonomy":"portfolio_skills","embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/portfolio_skills?post=18089"},{"taxonomy":"portfolio_tags","embeddable":true,"href":"https:\/\/www.wideautomation.com\/en\/wp-json\/wp\/v2\/portfolio_tags?post=18089"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}